CloudEngine 6800 Series Data Center Switches
- Classification:Data center switches
- Release time:2025-11-17
- Page views:0
CloudEngine 6800 Series Data Center Switches
- Classification:Data center switches
- Release time:2025-11-17
- Page views:0
The new generation of high-performance, high-density intelligent 10/25/50GE Ethernet access switches provides 40/100/200GE uplink ports.

1. High reliability
M-LAG ultra-fast failover, millisecond-level switching in case of link failure.
2. Intelligent Operation and Maintenance
Actively detect all network paths and monitor network health status in real time.
3. Open
Interoperable and open SDN switch wins gold award at Interop Japan.
Technical parameters
1. CE6855 Technical Parameters
| model | CE6855-48XS8CQ | CE6855-48T8CQ |
| port | 48 x 10GE+8 x 40/100GE | 48 x 10GE Base-T + 8 x 40/100GE |
| Switching capacity | 4.8Tbps/96Tbps | 4.8Tbps/96Tbps |
| Packet forwarding rate | 2000Mpps | 2000Mpps |
| reliability | LACP Hardware BFD (minimum packet interval 3.3ms) DPFR MoFRR | LACP Hardware BFD (minimum packet interval 3.3ms) DPFR MoFRR DPCF |
| O&M | Telemetry Netstream ERSPAN Enhancement IFIT Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility | Telemetry Netstream ERSPAN Enhancement IFIT Packet Event |
| Data center characteristics | 1588v2 | 1588v2 MACsec VXLAN routing 和 bridging BGP-EVPN M-LAG PFC, AI ECN |
| Power consumption | 138W | 227W |
| Power supply model | 600 W AC&240 V DC 1200 W DC | 1200W AC&240V DC 1200W DC |
| Power supply method | AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC | AC:90V to 290V;HVDC: 190V~290V DC:-38.4V DC~-72V DC;+40V DC~+57V DC |
2. CE6820 Technical Parameters
| model | CE6820-48S6CQ-A | CE6820H-48S6CQ |
| port | 48 x 10GE+6 x 40/100GE | 48 x 10GE+6 x 100GE |
| Switching capacity | 2.56Tbps/40.96Tbps | 2.56Tbps/40.96Tbps |
| Packet forwarding rate | 1080Mpps | 1080Mpps |
| cache | 21MB | 21MB |
| reliability | LACP Hardware BFD (minimum packet interval 3.3ms) | LACP Hardware BFD (minimum packet interval 3.3ms) |
| O&M | Telemetry ERSPAN Enhancement | Telemetry Netstream ERSPAN Enhancement |
| Data center characteristics | M-LAG ECN | M-LAG |
| Power consumption | 282W | 282W |
| Power supply model | 600W AC&240V DC 1000W DC 1200W HVDC | 600W AC 1000W DC 1200W DC |
| Power supply method | AC:90V~290V DC: -38.4V~-72V 240V HVDC: 190V~400V 380V HVDC: 190V~400V | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~400V 380V HVDC: 190V~400V |
3. CE6857 Technical Parameters
| model | CE6857E-48S6CQ | CE6857F-48S6CQ | CE6857F-48T6CQ |
| port | 48 x 10GE+6 x 40/100GE | 48 x 10GE+6 x 40/100GE | 48x10GE Base-T+6 x 40/100GE |
| Switching capacity | 4.8Tbps/96Tbps | 4.8Tbps/96Tbps | 4.8Tbps/96Tbps |
| Packet forwarding rate | 2000Mpps | 2000Mpps | 2000Mpps |
| cache | 32MB | 32MB | 32MB |
| reliability | LACP Differential segment | LACP Differential segment Hardware BFD (minimum packet interval 3.3ms) | LACP Differential segment Hardware BFD (minimum packet interval 3.3ms) |
| O&M | Telemetry Netstream sFlow | Telemetry Netstream sFlow ERSPAN Enhancement | Telemetry Netstream sFlow ERSPAN Enhancement |
| Data center characteristics | VXLAN routing 和 bridging BGP-EVPN M-LAG DCBX、PFC、ETS | VXLAN routing 和 bridging BGP-EVPN M-LAG DCBX、PFC、ETS | VXLAN routing 和 bridging BGP-EVPN M-LAG DCBX、PFC、ETS |
| Power consumption | 148W | 148W | 148W |
| Power supply model | 600W AC&240V DC 1000W -48V DC 1200W HVDC | 600W AC&240V DC 1000W -48V DC 1200W HVDC | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
| Power supply method | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400 |
4. CE6870 Technical Parameters
| model | CE6870-48S6CQ-EI-A |
| port | 48 x 10GE+6 x 40/100GE |
| Switching capacity | 2.16Tbps/19.44Tbps |
| Packet forwarding rate | 900Mpps |
| cache | 8GB |
| reliability | LACP Supports BFD for BGP/IS-IS/OSPF/Static Routing/VXLAN |
| O&M | Telemetry Netstream sFlow ERSPAN |
| Data center characteristics | VXLAN routing 和 bridging BGP-EVPN M-LAG DCBX、PFC、ETS |
| Power consumption | 194 W |
| Power supply model | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
| Power supply method | AC: 90V~290V DC: -38.4V~-72V 380V HVDC: 190V~400V |
5. CE6881 Technical Parameters
| model | CE6881-48S6CQ | CE6881-48T6CQ | CE6881H-48S6CQ | CE6881H-48T6CQ |
| port | 48 x 10GE+6 x 40/100GE | 48 x 10 GE Base-T+6 x 40/100GE | 48 x 10GE+6 x 40/100GE | 48 x 10 GE Base-T+6 x 40/100GE |
| Switching capacity | 4.8Tbps/96Tbps | 4.8Tbps/96Tbps | 4.8Tbps/96Tbps | 4.8Tbps/96Tbps |
| Packet forwarding rate | 2000Mpps | 2000Mpps | 2000Mpps | 2000Mpps |
| reliability | LACP Differential segment Hardware BFD (minimum packet interval 3.3ms) | LACP Differential segment Hardware BFD (minimum packet interval 3.3ms) | LACP Hardware BFD (minimum packet interval 3.3ms) | LACP Hardware BFD (minimum packet interval 3.3ms) |
| O&M | Telemetry Netstream sFlow ERSPAN Enhancement | Telemetry Netstream sFlow ERSPAN Enhancement | Telemetry Netstream ERSPAN Enhancement | Telemetry Netstream ERSPAN Enhancement |
| Data center characteristics | VXLAN routing 和 bridging BGP-EVPN M-LAG PFC、ECN VXLAN Mapping | VXLAN routing 和 bridging BGP-EVPN M-LAG PFC、ECN | VXLAN routing 和 bridging BGP-EVPN M-LAG PTP | VXLAN routing 和 bridging BGP-EVPN M-LAG PTP |
| Power consumption | 194W | 347W | 194 W | 347W |
| Power supply model | 600W AC&240V DC 1000W -48V DC 1200W HVDC | 600W AC&240V DC 1000W -48V DC 1200W HVDC | 600W AC&240V DC 1000W -48V DC 1200W HVDC | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
| Power supply method | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V | AC: 90V~290V DC: -38.4V~-72V 380V HVDC: 190V~400V | AC: 90V~290V DC: -38.4V~-72V 380V HVDC: 190V~400V |
6. CE6885 Technical Parameters
| model | CE6885-48YS8CQ | CE6885H-48YS8CQ | CE6885L-48YS8CQ | CE6885-LL-56F |
| port | 48 x 10/25GE/50GE+8 x 40/100GE/200GE | 48 x 25GE/50GE+8 x 100GE/200GE | 48 x 25GE+8 x 40/100GE | 48 x 10/25GE + 8 x 40/100GE (Uplink ports are unavailable when low latency mode is enabled) |
| Switching capacity | 8T/128T | 8T/128T | 8T/128T | 8T/128T |
| Packet forwarding rate | 2400Mpps | 2400Mpps | 2400Mpps | 1200Mpps |
| reliability | LACP Hardware BFD (minimum packet interval 3.3ms) DPFR MoFRR Supports fine-grained micro-segmentation security isolation (IPv4 and IPv6) | LACP Hardware BFD (minimum packet interval 3.3ms) DPFR MoFRR Supports fine-grained micro-segmentation security isolation (IPv4 and IPv6) | LACP Hardware BFD (minimum packet interval 3.3ms) DPFR MoFRR DPCF | LACP Hardware BFD (minimum packet interval 3.3ms) MoFRR |
| O&M | Telemetry Netstream ERSPAN Enhancement IFIT Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility | Telemetry Netstream ERSPAN Enhancement IFIT Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility | Telemetry Netstream ERSPAN Enhancement IFIT Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility | Telemetry Netstream ERSPAN Enhancement Edge intelligence Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility |
| Data center characteristics | 1588v2 MACsec VXLAN routing 和 bridging BGP-EVPN M-LAG PFC, AI ECN VXLAN over IPv6 VXLAN Mapping | 1588v2 MACsec VXLAN routing 和 bridging BGP-EVPN M-LAG PFC, AI ECN VXLAN over IPv6 VXLAN Mapping | 1588v2 VXLAN routing 和 bridging BGP-EVPN M-LAG PFC, AI ECN VXLAN over IPv6 | L2/L3 minimum forwarding latency: 320ns~350ns 1588v2 M-LAG PFC, AI ECN VXLAN over IPv6 |
| Power consumption | 147W | 147W (100% load, 24x25G+4x100G copper ports, ambient temperature, dual AC power supply) 166W (100% load, 24x25G+4x100G port short-range optical modules, room temperature, dual AC power supply) | 48x25G+8x100G: 144W (100% load, 24x25G+4x100G copper ports, ambient temperature, dual AC power supply) 163W (100% load, 24x25G+4x100G port short-range optical modules, room temperature, dual AC power supply) | 127W |
| Power supply model | 600W AC&240V DC 1200W DC | 600W AC&240V DC 1200W DC | 600W AC&240V DC 1200W DC 400W DC | 600W AC&240V DC 1200W DC |
| Power supply method | AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC | AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC | 600W AC & 240V DC Power Supply Module: AC: 100V AC~240V AC, 50/60Hz; DC: 240V DC 1200W DC power supply module: -48V DC to -60V DC; +48V DC 400W DC power supply module: -48V DC to -60V DC; +48V DC | AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+40V DC to +57V DC |
7. CE6863 Technical Parameters
| model | CE6863E-48S6CQ | CE6863H-48S6CQ |
| port | 48 x 10/25GE+6 x 40/100GE | 48 x 10/25GE+6 x 40/100GE |
| Switching capacity | 4.8Tbps/96Tbps | 4.8Tbps/96Tbps |
| Packet forwarding rate | 2000Mpps | 2000Mpps |
| cache | 42MB | 42MB |
| reliability | Differential segment Hardware BFD (minimum packet interval 3.3ms) LACP | LACP Hardware BFD (minimum packet interval 3.3ms) |
| O&M | Telemetry Netstream sFlow ERSPAN Enhancement | Telemetry Netstream ERSPAN Enhancement |
| Data center characteristics | VXLAN routing 和 bridging BGP-EVPN M-LAG PFC、ECN | VXLAN routing 和 bridging BGP-EVPN M-LAG PTP |
| Power consumption | 226W | 226W |
| Power supply model | 600W AC&240V DC 1000W -48V DC 1200W HVDC | 600W AC&240V DC 1000W -48V DC 1200W HVDC |
| Power supply method | AC: 90V~290V DC: -38.4V~-72V 240V HVDC: 190V~290V 380V HVDC: 190V~400V | AC: 90V~290V DC: -38.4V~-72V 380V HVDC: 190V~400V |
8. CE6885-SAN Technical Specifications
| model | CE6885-SAN-56F |
| port | 48 x 10/25/50GE+8 x 100/200GE *Use only in centralized storage scenarios |
| Switching capacity | 8Tbps |
| Packet forwarding rate | 2400Mpps |
| cache | 64MB |
| reliability | LACP Hardware BFD (minimum packet interval 3.3ms) DPFR |
| O&M | Telemetry Netstream ERSPAN Enhancement IFIT Packet Event: Packet Loss Visibility, Ultra-Long Latency Visibility |
| Data center characteristics | 1588v2 MACsec VXLAN routing 和 bridging BGP-EVPN M-LAG PFC, AI ECN |
| Intelligent lossless network | AI ECN PFC deadlock prevention iNOF NPCC(Network-based Proactive Congestion Control) ECN Overlay |
| Power consumption | 48x25G+8x100G: 147W (100% load, 24x25G+4x100G port copper cable, room temperature, dual AC power supply) 166W (100% load, 24x25G+4x100G port short-range optical module, room temperature, dual AC power supply) 48x50G+8x200G: 177W (100% load, 24 50G copper ports, 4 200G short-distance optical modules, room temperature, dual AC power supply) |
| Power supply model | 600 W AC&240 V DC 1200 W DC |
| Power supply method | AC:90V to 290V;HVDC: 190V~290V DC: -48V:-38.4V to -72V; +48V DC:+38.4V to+60V |